This function requires the Advanced License and up or the Show Control Module. See Licenses and functions.
An SC LAN DMX512 in/out can only be used if its IP address lies within the Wings Vioso RX computer address space. Instructions on how to set the IP address can be found in the SC LAN Module operating instructions.
Click category Devices in the Media Pool.
Right-click some free space in the Media Pool and select Stumpfl SC LAN SC LAN DMX512 in/out.
Enter the module IP address. The last address group can be changed by clicking on Network. If the module is not detected and the IP address not known, you can use our software ISEO Designer to find out about it or alter it if necessary.
Leave the minimum cycle time at the default value of 30 milliseconds. Extending this time may save performance, but it should not be less than 30 ms.
If you want to execute trigger functions via DMX you place a checkmark next to Execute trigger with DMX channel and enter the corresponding channel.
Close the dialog by clicking OK.
In the Media Pool on the left under Devices click SC LAN DMX512 in/out, to highlight the device port.
Right-click the right Media Pool section and select Add devices.
Place a checkmark next to the DMX-Out and enter the number of channels that need to be added.
Finally, click OK.
You can now drag the switch outputs into a universal track and program the appropriate switching functions.